DN 20 Distribution Components

8 Item(s)

Set Descending Direction
per page

Grid  List 

  1. Wall brackets for just one DN20 unit

    Wall brackets for just one DN20 unit

    Bracket for mounting a single DN20 pump set to the wall. Learn More
  2. Wall brackets DN20 for manifold 'L'

    Wall brackets DN20 for manifold 'L'

    Two L-shaped wall brackets for fixing any of the DN20 manifolds to the wall. Learn More
  3. Insulated tubing kit for hydraulic separator

    Insulated tubing kit for hydraulic separator

    Insulated tubing kit TB60 for connection of vertical hydraulic separator to zone manifolds DN 20 "C60" 2-3-4/F Learn More
  4. DN20 Hydraulic Separator CP60

    DN20 Hydraulic Separator CP60

    CP60 is a compensation chamber which renders connected independent hydraulic circuits. It is usually installed when the primary circuit pump interacts with one or more pumps of the secondary circuit in the same system. Therefore, it avoids problems relating to flow rate variations and circuit prevalence. CP60 may be installed vertically or horizontally and also acts as an air separator. It is made in square section steel, painted and insulated with EPP. Learn More
  5.  Manifold DN20 “C60/2F” 2 Zone

    Manifold DN20 “C60/2F” 2 Zone

    Two zone manifold DN 20 "C60 DUO-SYSTEM" double independent chamber zone manifolds are made of square section painted steel and insulated with black EPP. DUO-SYSTEM allows connection or separation of flow and return chambers by twisting a cap. Thanks to this feature, the manifold can be used as a distributor for systems with several interacting pumps which work between primary circuit (boiler) and secondary circuit (heating systems). Learn More
  6. Manifold DN20 “C60/3F” 3 Zone

    Manifold DN20 “C60/3F” 3 Zone

    Three zone manifold DN 20 "C60 DUO-SYSTEM" double independent chamber zone manifolds are made of square section painted steel and insulated with black EPP. DUO-SYSTEM allows connection or separation of flow and return chambers by twisting a cap. Thanks to this feature, the manifold can be used as a distributor for systems with several interacting pumps which work between primary circuit (boiler) and secondary circuit (heating systems). Learn More
  7. No mixing unit DN 20 - 3/4" "SA-90" with Wilo Yonos Para 15/1-6  (new high efficiency pump)

    No mixing unit DN 20 - 3/4" "SA-90" with Wilo Yonos Para 15/1-6 (new high efficiency pump)

    The unmixing unit DN 20 - ¾" "SA-90" is suitable for high temperature circuits (radiators, fan coils and boilers). The circulator, which is 130 mm high, has 1" connections. It is connected up and down stream with 2 flanged ball valves, so that it may be checked or changed at any moment without having to empty the plant. The temperature of flow and return can be checked using the two thermometers. A check valve is inside the return spacer fitting. An over pressure bypass unit can be applied to the upper part of the ball valves). All seals are assured by flat fittings and gaskets. The standard unit is supplied with right flow. It may be converted to left flow directly by the installer inverting the spacer fitting and pump positions. Insulation is of black EPP 40 g/l. The connections of unit are ¾" F and can be connected at any commercial connection. Learn More
  8. Mixing unit DN 20 - 3/4" "HV3-90" with Wilo Yonos Para 15/1-6  (new high efficiency pump)

    Mixing unit DN 20 - 3/4" "HV3-90" with Wilo Yonos Para 15/1-6 (new high efficiency pump)

    DN 20 - ¾" "HV3-90" mixing unit is a system with a 3-way mixing valve controlled by a rotary electric actuator and is connectable to any type of controller. The valve has 2 bypasses: - upper bypass (plant circuit): takes a part of the plant return water and runs it into flow, thus allows the recovery of heat and the balance of flow temperature; ideal for underfloor heating systems; - lower bypass (boiler circuit): allows to bypass the flow fluid when there is a pump in the boiler and the valve is closed. The pump, which is 130 mm high, has 1" connections. It can be intercepted through the closure of the upstream mixing valve and the downstream flanged ball valve for easy checking or replacement at any time without having to empty the plant. The temperature of flow and return can be checked using the two thermometers. A check valve is inside the return spacer fitting. An over pressure bypass unit can be applied to the upper part of the ball valves. All seals are assured by flat fittings and gaskets. The standard unit is supplied with right flow. It may be converted to left flow directly by the installer inverting the space fitting and pump positions and acting on the valve following the instructions. Insulation is of black EPP 40 g/l. The connections of unit are ¾" F and can be connected at any commercial connection. Learn More

8 Item(s)